Electric Showers

Click on each of the questions to reveal the answers

 

A newly installed T300si, when started the low water pressure light is on and there is only cold water from the showerhead, why?

Check that the commissioning procedure has been carried out correctly as detailed in the fitting instructions. Check the inlet filter is not blocked and establish that water pressure and flow meets the specified minimum.

Top  
 

Can I use push-fit pipe and fittings to install my Triton electric shower?

Yes, you can use push-fit plumbing except for the final connection onto the shower inlet, which must be a 15mm compression fitting to ensure a watertight connection.

Top  
 

Do I have to fit a double - pole isolation switch when I install my Triton electric shower?

Yes, for the purpose of future servicing of the shower a ceiling or wall mounted DP isolation switch is required. It is also good practice to isolate the shower when not in use.

Top  
 

Does the wiring to an existing electric shower need upgrading when fitting a higher kilowatt rated unit?

Not necessarily, it will depend on the existing cable size and installation characteristics. A site inspection by a competent electrician is required to confirm if the existing cable and fuse will need upgrading.

Top  
 

Having reset the MCB my electric shower is now not heating the water fully, why?

The most likely reason why the unit is not heating the water fully is that a heating element has failed. The elements can be tested for continuity using a multi-meter. If open circuit a new heater assembly is needed.

Note: If an element has failed other parts within the unit may have been affected it is therefore important to check all the electrical circuits in the unit for signs of failure.

Top  
 

How can I work out the running cost of an electric shower?

To establish the electricity cost firstly multiply the kW per hour tariff you are paying by the kW rating of the shower. The cost per shower is then dependant on the number of showers taken per hour.

Example for an 8kW shower unit.

Electricity tariff at 12 pence per kW hour multiplied by 8 = Total cost of 96 pence per hour.

Number of 5-minute showers taken in 1 hour = 12

96p divided by 12 = Total cost of 8 pence for a 5 minute shower

Top  
 

If there is not enough mains water pressure to operate an electric shower what can be done?

If the mains water pressure is insufficient then a Triton T450i single impeller pump can be used to supply water to most electric showers. Alternatively an integral pumped shower such as the T90xr can be installed. However, these are not suited for a 10.5kw or thermostatic unit.


Note: pumped showers must be fed from a cold water cistern they must not be connected to the mains cold water supply.

Top  
 

Is it possible to connect an electric shower to an electric circuit that is feeding another appliance?

No, an electric shower must have its own dedicated power supply.

Top  
 

My electric shower is indicating low pressure what should I check?

  • Check isolation valves are fully open

  • Check inlet filter is not blocked with debris

  • Check minimum required water pressure and flow is available at the inlet to the shower.

Top  
 

My electric shower runs hot then cold (cycling), why?

  • The flow rate of water through the unit could be too low, causing the thermal cut-out to activate. Check there are no restrictions to the flow of water through the unit

  • There could be a possible sudden drop in water pressure, falling below the minimum required. This could be because water is being drawn off elsewhere in the house e.g. the washing machine, or a toilet flushing.

  • Seasonal ambient water changes may require a lower setting to be selected.

Top  
 

My electric shower will not turn off the water what should I do?

  • Check that the front cover has been fitted correctly with no distortion to the backplate

  • On units fitted with a commissioning link, check that it has been removed during installation (see fitting instructions for further advice)

Top  
 

My Triton electric shower is under warranty and has a fault, what is the procedure?

If the shower is under warranty request an engineer visit via this site or call 02476 378 495 to arrange a visit under the terms and conditions of the warranty

Top  
 

The water flowing from my electric shower is cold/too cool, what can I check?

  • Is electricity turned on to the unit?

  • Check that the temperature control is set to the correct number for the time of year (you will need a higher number in the winter than in the summer)

  • Check that the power selector (if available) is set to 'High'

  • On units fitted with a 'Low Pressure' indicator, check to see if it has been activated. If it has, then it is advisable to check for blockages in the inlet filter and/or have your mains water pressure checked

  • On units not fitted with a 'Low Pressure' indicator, pressure could still be the problem, so it is advisable to have this checked prior to an engineer call-out

  • Check that the front cover has been fitted correctly with no distortion to the backplate.

Top  
 

There is no water flowing from my electric shower, what should I check?

  • Is water turned on to the unit?

  • Is electricity turned on to the unit? 

  • Is the inlet filter blocked? 

  • Are the front cover and any start/stop connecting cable fitted correctly?

Top  
 

Water from my electric shower is not getting hot enough, why?

Check the temperature control and power setting is on the correct setting for the time of year.

Check the temperature control (flow control valve) is regulating the flow of water through the unit, there should be a noticeable reduction in flow when turning towards the hotter settings.

Using an electrical test meter the following electrical components can be checked for continuity:

  • Heating elements

  • Micro-switches

  • Thermal cut-outs

  • If the unit is electronic then voltage tests have to be carried out on the PCB/s (printed circuit board/s) in the unit.

 

Top  
 

Water from my electric shower is too hot, why?

  • Check that the Stop Tap is fully open

  • Check that the sprayplate of the showerhead is clean. Check if an acceptable temperature is achieved by removing the showerhead from the shower hose

  • Check the internal lining of the shower hose is not collapsed

  • If the shower is delivering a flow of less than 5 litres/minute on a temperature setting of '1', then check for blockages in the inlet filter. Use a bucket and stopwatch to check flow rate

  • If the problem is occurring during a period of hot weather, then you may be experiencing high incoming ambient water temperatures and /or borderline water pressure. Try setting the power selector (if available) to 'Low' and adjusting the temperature control to suit.

Top  
 

What is a PRD (pressure relief device)?

The PRD is a safety device designed to relieve abnormal pressure from within the heater assembly of an electric shower when a restriction occurs on the shower outlet i.e. blocked showerhead, collapsed shower hose. If activated it will be necessary to fit a new one

Top  
 

What is the minimum water pressure and flow rate required for Triton Electric Showers?

The minimum water pressure required depends upon the model and its kilowatt rating.

Some units will continue to operate at a reduced flow performance on a minimum running pressure/flow of 0.5bar at 8 litres per minute. However for full flow performance from all electric showers the following pressure and flow is required.   

  • 7kW to 8.5kW showers require a minimum running pressure of 1 bar at a minimum flow rate of 8 litres per minute

  • 9kW and 9.5kW showers require a minimum running pressure of 1 bar at a minimum flow rate of 9 litres per minute

  • 10.5 kW showers require a minimum running water pressure of 1.5 bar at a minimum flow rate of 11 litres per minute

Top  
 

What points need to be considered when replacing an existing electric shower?

Considerations when replacing an electric shower are:

  • Dimensions of the unit (will the replacement shower cover existing tiles and screw fixings)

  • Cable and water entry points (are they compatible)

  • Kilowatt rating of the unit (is the existing cable and fuse size adequate for a higher kW rating )

  • Incoming electricity supply to the property (is the supply adequate i.e. 80 or 100amp for a higher kW rating )

Top  
 

What size electric cable is required for an electric shower?

The size of cable that can be used for an electric shower depends on a number of factors which includes, the kilowatt rating of the shower, the method of cable installation, any de-rating factors and the length of circuit. In some cases 6mm² cable will be adequate for a shower rated up to 8kW. For showers above 8kW it may be necessary to install 10mm² cable.

In order to comply with Part P building regulations a competent installer familiar with the requirements of the current I.E.E regulations must assess the proposed circuit in order to select the correct cable size.

Top  
 

What size fuse do I require for an electric shower?

The fuse size must be equal to or the nearest size above the kilowatt rating of the shower i.e.

  • 7kW = 30/32amp mcb

  • 7.5kW = 32amp mcb

  • 8kW = 40amp mcb

  • 8.5kW = 40amp mcb

  • 9.5kw = 40/45amp mcb

  • 10.5kW = 45/50amp mcb

Top  
 

What type of plumbing fitting is required to connect onto the inlet of Triton electric showers?

The range of mains fed electric showers and the T90xr pumped electric shower require a 15mm compression fitting to be used.

The T80si pumped shower has a 15mm push – fit inlet connection.

Top  
 

What will happen if the incorrect fuse size is fitted for an electric shower?

If an under-rated fuse is used it will be overloaded and will keep tripping out. If the fuse rating is too large it will not disconnect the supply quick enough under a short circuit fault condition. To avoid these problems the correct size fuse/mcb must be fitted for the kW rating of the unit in accordance with the I.E.E. regulations. Sizes required are:

  • 7kW = 30/32amp mcb.

  • 7.5kW = 32amp mcb

  • 8kW = 40amp mcb

  • 8.5kW = 40amp mcb

  • 9.5kw = 40/45amp mcb

  • 10.5kW = 45/50amp mcb

Top  
 

When I turn on my electric shower water starts leaking out from the bottom of the unit, why?

If water is leaking from a clear plastic tube or small plastic elbow in the unit, then the Pressure Relief Device (PRD) has been activated. The most common reasons for the PRD to activate are that the showerhead has become blocked or there is a restriction in the shower hose. A replacement can be ordered from our online spare parts store or by calling 02476 378 495

If the water is not leaking from the clear plastic tube, then isolate the electricity supply to the shower and call 02476 378 495 for advice.

Top  
 

Where is the filter situated in a Triton electric shower?

The filter will be found in the inlet connection. In some units it will be necessary to disconnect from the water supply to access the filter.

Top  
 

Where is the serial number located on a Triton Electric shower?

A rating label is located on the underside of the unit, which includes the model name, kW rating and the manufacture date code (ACCEPTABLE FOR WARRANTY REGISTRATION). Inside the unit there is a further product-rating label, which has the same information and also the serial number.

Top  
 

Which electric shower do you recommend as a replacement for an old one?

The T80z Fast-Fit is recommended as a replacement for all previous models of T80 i.e. T80Mk3, T80i, T80si, T80xr and T80z.

The T80z Fast-Fit is also an ideal replacement for other makes and models as water and cable entry points are on both the left and right hand side of the unit.

Top  

 

 

 

 

 

 

TRITON Videos

Unsure about showers? Watch our "back to basics" shower videos!

Click to view

Help me Choose

Find the right shower for you with Triton's shower guide and product videos

Click to view

Clearance Deals

Scary deals on electric showers, mixer showers and shower accessories

Click to view

Browse all Showers

Browse through Triton's electric showers, mixer showers & power showers

Click to view

TRITON Brochure

Download the latest Triton shower brochure

Click to view

Where to Buy

Find your nearest Triton shower stockist

Click to view

Cookie Policy »