Received an error code with your ENlight® product?

In the event that a fault is detected, an error message will be displayed on the ENlight® display.

 

The table below provides guidance on what to do next if a particular error message is displayed. If any further assistance is required, please contact Triton Customer Experience.

 

Error Code

Error Description

Solution (other than contact Triton CX)

OverTemp This message appears if the outlet temperature has reached an excessive temperature. Isolate the power to the product, wait for 10 seconds, then resupply the power. Then try using the product again.
Low Flow This message appears if the incoming flow has dropped to an unacceptably low value whilst showering. Check the incoming water supply for the product. Ensure that the outlet is not restricted.
Fault 1 This message appears if the power relay has failed. Please contact Triton Customer Experience.
Fault 2 This message appears if the outlet thermistor is not detected. Isolate the power to the product, wait for 10 seconds, then resupply the power. Then try using the product again.
Fault 3 This message appears if a short circuit has been dectected in the outlet thermistor. Isolate the power to the product, wait for 10 seconds, then resupply the power. Then try using the product again.
Fault 4 This message appears if the heater can thermistor is not detected. Isolate the power to the product, wait for 10 seconds, then resupply the power. Then try using the product again.
Fault 5 This message appears if a short circuit has been dectected in the heater can thermistor. Isolate the power to the product, wait for 10 seconds, then resupply the power. Then try using the product again.
Faul 6 This message appears if one of the relays has reached an excessive temperature. Isolate the power to the product, wait for 10 minutes to allow the relay to cool down, then resupply the power and try using the product again.
Fault 7 This message appears if one of the relays has reached an excessive temperature on three occasions. Please contact Triton Customer Experience.
Fault 8 Pressure switch has failed. Please contact Triton Customer Experience.