Does the wiring to an existing electric shower need upgrading when fitting a higher kilowatt rated unit?
Not necessarily, it will depend on the existing cable size and installation characteristics. A site inspection by a competent electrician is required to confirm if the existing cable and fuse will need upgrading.
What size fuse do I require for an electric shower?
The fuse size must be equal to or the nearest size above the kilowatt rating of the shower i.e. 7kW = 30/32amp mcb. 7.5kW = 32amp mcb. 8kW = 40amp mcb. 8.5kW = 40amp mcb. 9.5kw = 40/45amp mcb. 10.5kW = 45/50amp mcb
How can I work out the running cost of an electric shower?
To establish the electricity cost firstly multiply the kW per hour tariff you are paying by the kW rating of the shower. The cost per shower is then dependant on the number of showers taken per hour. Example for an 8kW shower unit. Electricity tariff...
What size electric cable is required for an electric shower?
The size of cable that can be used for an electric shower depends on a number of factors which includes, the kilowatt rating of the shower, the method of cable installation, any de-rating factors and the length of circuit. In some cases 6mm cable will...
What type of plumbing fitting is required to connect onto the inlet of Triton electric showers?
With the exception of the T80 Pro-Fit, the range of mains fed electric showers and theT90xrpumpedelectric showerrequire a 15mm compression fitting to be used. TheT80si pumped shower has a 15mm push fit inlet connection. The T80 Pro-Fit can use compression...
What is the minimum water pressure and flow rate required for Triton Electric Showers?
The minimum water pressure required depends upon the model and its kilowatt rating. Some units will continue to operate at a reduced flow performance on a minimum running pressure/flow of 0.5bar at 8 litres per minute. However for full flow performance...
Which electric shower do you recommend as a replacement for an old one?
TheT80zFast-Fitor T80 Pro-Fit are recommended as a replacement for all previous models of T80 i.e. T80Mk3, T80i, T80si, T80xr and T80z. TheT80zFast-FitorT80 Pro-Fitarealso ideal replacement options for other makes and models as water and cable entry ...
If there is not enough mains water pressure to operate an electric shower what can be done?
If the mains water pressure is insufficient then aTritonT450i single impeller pump can be used to supply water to most electric showers. Alternatively an integral pumped shower such as theT90xrcan be installed. However, these are not suited for a 10....
How do you fit the hoses supplied with a DuElec® electric shower?
Please ensure you pay special attention to the installation instructions and how the hoses are fitted to the diverter.   Step 1   Begin by uncoiling both hoses, check hose lengths and set aside the longer hose.   Shorter Shower Hose...